Electrically Heated Detail Page

S429K448A
Electrically Heated Pressure Cleaning Systems
Electrically Heated Application

S830K2472A Cat
Commercial Duty Propane Fired P420P30E 

  • Unique, reliable design  
  • CSA approved / fully automatic
  • Environmentally friendly / no exhaust fumes or open flame
  • 2 year heater coil warranty / 3 year heater element warranty
  • Belt-driven, oil-bath plunger pump
  • Auto start / stop circuit controlled by trigger gun activation 
  • instant hot pressurized water / no warm up time required 
  • Large 80 and 130 gallon heat exchanger tanks allow for continuous recovery to maintain optimum performance 
  • No hard water scale build up or heater element to burn out as no direct immersion of elements allowed into water being pumped
  • Transfer fluid in heat exchanger treated to prevent corrosion or galvanic action
  • Thermo blanket lined tank provides almost 100 % energy input / output efficiency
    (all power is used to heat water)
  • Thermostatically controlled heat exchanger with low water shut off 
  • Downstream chemical injection (8gpm or larger models include upstream chemical injection)
  • Cold water through pump for long life
  • Automatic high temperature shut down (thermo probe) for pump protection
  • Ideal for centralized systems with multi-station outlets
  • Available with 24, 48, 72 & 99 kW input and working pressures of up to 4000 psi
  • Complete with 50 ft. steel braid pressure hose, trigger gun, variable pressure wand and hardened stainless steel nozzle (8 gpm or larger models include 2 sets)
  • Multi-gun systems for high capacity cleaning

UNIQUE DESIGN FEATURES INCLUDE

  1. NO direct immersion of elements into water being pumped - no scale build-up or element burn out as is common in direct immersion type, electrically heated systems
  2. LARGE Heater B.T.U. storage tank allows for continuous recovery even when the gun is triggered off. This provides for good heat retention at higher flow rates. Water in tank is treated with Permafilm P to prevent corrosion and galvanic action.
  3. COIL - Stainless steel coil provides efficient heat transfer from heat storage solution to high pressure water passing through the coil. No water/soap scale will form as the maximum coil temperature never exceeds 190°F (fuel fired coils are subject to skin temperature of up to 750°F and can therefore scale up). Easy coil repair or replacement if ever required.
  4. WATER is heated on the pressurized side of the pump which allows for a longer pump life.
  5. ELEMENTS - calrod heaters are of tubular design and encased in an incaloy sleeve for
    long life. Each pin may be replaced independently (not like screw plug type as used
    by others) at 1/3 of the cost.
  6. SAFETY low heater solution cut off switch is placed in the tank to shut off the power to the elements should the level drop. The tank temperature is thermostatically controlled with a 24 VAC circuit.
  7. THERMO BLANKET - The tank is fully insulated to provide almost 100% energy input/output efficiency (all power is used to heat water)
  8. INSTANT hot pressurized water. Since the heater is always at operating temperature
    you get hot water the moment you trigger the gun. No cool down procedure is required
    after use. A 5 minute wash job is 5 minutes only.
  9. TROUBLE FREE - Fully automatic heat exchanger (no operator controls). Fully automatic START/STOP motor circuit. Machine may be operated from any remote location by simply triggering the gun on and off. Solid state shut down after 10 seconds.
  10. NO OPEN FLAME - can be used in environmentally sensitive areas. May be installed
    almost anywhere - under stairway, under work bench, compressor room, storage room,
    shop area, etc.

Specifications

Flow

Pressure

Heater

Motor

Total Amps
3-Phase

Size-Inches

MODEL

 GPM

PSI

 Input

 H.P.

208V

460V

575V

W"xL"xH"

S411K424A

 4

 1100

 24KW

 3

 72.3

 33.3

 26.6

 24/32/50

S411K448A

 4

 1100

 48KW

 3

 134.8

 62.2

 49.7

 24/32/50

S420K424A

 4

 1900

 24KW

 5

 77.1

 35.5

 28.4

 24/32/50

S420K448A

 4

 1900

 48KW

 5

 139.6

 64.4

 51.8

 24/32/50

S420K472A

 4

 1900

 72KW

 5

 --

 93.3

 74.4

 24/32/50

S429K424A

 4

 2900

 24KW

 7.5

 85

 39.1

 31.3

 24/32/50

S429K448A

 4

 2900

 48KW

 7.5

 147.5

 68

 54.4

 24/32/50

S429K472A

 4

 2900

 72KW

 7.5

 --

 96.9

 77.6

 24/32/50

S440K448A

 4

 4000

 48KW

 10

 154

 70.9

 56.7

 24/32/50

S440K472A

 4

 4000

 72KW

 10

 --

 99.8

 79.9

 24/32/50

S543K448A

 5.4

 3000

 48KW

 10

 154

 70.9

 56.7

 24/32/50

S543K472A

 5.4

 3000

 72KW

 10

 --

 99.8

 79.9

 24/32/50

S562K448A

 5.6

 2000

 48KW

 7.5

 147.5

 68

 54.4

 24/32/50

S562K472A

 5.6

 2000

 72KW

 7.5

 --

 96.9

 77.6

 24/32/50

S612K448A

 6

 1200

 48KW

 5

 139.6

 64.4

 51.8

 24/32/50

S620K448A

 6

 2000

 48KW

 7.5

 147.5

 68

 54.4

 24/32/50

S620K472A

 6

 2000

 72KW

 7.5

 --

 96.9

 77.6

 24/32/50

S812K2448A*

 8

 1200

 48KW

 7.5

 147.5

 68

 54.4

 53/48/40

S812K2472A*

 8

 1200

 72KW

 7.5

 --

 96.9

 77.6

 53/48/40

S820K2448A*

 8

 2000

 48KW

 10

 154

 70.9

 56.7

 53/48/40

S820K2472A*

 8

 2000

 72KW

 10

 --

 99.8

 79.9

 53/48/40

S830K2448A*

 8

 3000

 48KW

 15

 165

 75.9

 60.7

 53/48/40

S830K2472A*

 8

 3000

 72KW

 15

 --

 104.8

 83.9

 53/48/40

Contact Us:
Ideal Solutions, 2560 Palumbo Drive, Lexington, Kentucky, United States 40509
Phone: 1-866-673-3963 FAX: 1-859-266-2717
E-mail
: msweetman@idealsolutionsonline.us
Or Use Our Contact Form